Diffuser Dampers
Remote Control Damper (WRCD) and Wireless Remote Control (WRC)
One piece of heating and cooling equipment often services more than just one room or office. Differences in both climatic exposure as well as personal needs can result in an uncomfortable environment for some occupants. No matter how well a system is designed and balanced, providing comfort to individuals is an unending task. The model WRCD Damper uses a wireless remote control to incrementally open and close a volume damper allowing the occupant total control over their comfort. It is a 24 volt powered damper that is designed to install between a lay-in diffuser and the supply duct for the purpose of regulating the volume of airflow into a specific space. Easily installed, the WRCD is designed to be a quick cure for areas where occupants require the ability to frequently adjust the airflow.
• Designed for use with Wireless Remote Control
• The occupant can adjust the room airflow from any location in the room
• A new and unique cure to an old and continual problem.
• The WRCD eliminates the employee’s desire to constantly adjust system controls which can result in
higher heating and cooling costs.
• New product to add value for the Commercial Service Contractor.
Remote Control Damper Damper (WRCD) Lit Sheet >
Remote Control Damper (WRCD) Installation Instructions >
Wireless Remote Control (WRC) Installation Instructions >
Wiring Multiple Dampers Installation Instructions >

Round Diffuser Damper (RCD) and Controls:
Manual Wall Control (MWC) & Occupancy Sensor (OSL)
Room or office occupancy can vary greatly as a result of meetings, travel or daily schedules. The
DuroZone Diffuser Damper is an efficient way to condition the spaces that are used sporadically
or intermittently such as a conference room or an empty office. Utilizing the Diffuser Damper in
these areas can minimize the waste of energy that results from conditioning unoccupied areas.
The DuroZone Diffuser Damper can be installed with either of two control options:
1) A Manual Wall Control (MWC) can be wired directly to the damper. The occupant can use the switch to incrementally adjust the damper setting.
2) An Occupancy Sensor (OSL) can be wired directly to the damper. As someone enters the space and turns on the lights, the sensor detects the lights being turned on and opens the damper to the pre-set occupied airflow setting. When the lights are turned off the sensor reacts and sets the damper to its minimum (vacant) setting. Both the Manual Wall Control (MWC) and the Occupancy Sensor (OSL) options allow the occupant to
have greater control over their comfort and the building owner greater control over energy use.
Round Diffuser Damper (RCD) Lit Sheet >
Round Diffuser Damper (RCD) Installation Instructions >
Manual Wall Control (MWC) Installation Instructions >
Occupancy Sensor (OSL) Installation Instructions >
Wiring Multiple Dampers Installation Instructions >











