ZONING PANELS

DuroZone RED-4 ZONING PANEL


Go To RED-4 Complete System Example

Go To RED-4 Instruction Manual (PDF)

Item No. 35234, RED-4  Zoning Panel
Item #35234 RED-4 Zoning Panel
  • Controls four zones.
  • Zone4 damper can be used as fresh air damper.  Timer on panel sets minutes of fresh air per hour.
  • Two-stage heating and two-stage cooling for gas/electric systems and three-stage heating and two-stage cooling for heat pump systems.
  • Compatible with gas/electric, oil, electric and hydronic systems and both conventional and dual fuel heat pumps.
  • Optional supply air temperature sensor used to limit supply air temperature and prevent over-heating and freeze-up.
  • Maximum and minimum supply air temperatures can be set on panel.
  • Optional outdoor air temperature sensor to limit use of second stage heating in moderate weather.
  • Optional outdoor air temperature sensor used with dual fuel heat pumps to control switch-over to fossil fuel heating without the use of external thermostats or relays.
  • Compatible with low cost, heat-cool thermostats.
  • Compatible with automatic change-over thermostats allowing any zone to call for heating or cooling.
  • Second and third stage controlled by timer and timer can be set on the panel.
  • Heat pump thermostat can be used in Zone1 for emergency heat control.
  • Optional purge cycle at the end of heating or cooling call.
  • Limit use of second stage heating and cooling when less than half the zones are calling.
  • One-Zone operation eliminates resetting all thermostats when going on vacation.  All dampers and HVAC system are controlled by the Zone1 thermostat.
  • Compatible with most 24VAC powered, battery powered or power robbing thermostats.
  • Compatible with DuroZone zoning dampers models RD, MB and MS.
  • Automatic Contractor Test checks all wiring, dampers, thermostats and the HVAC system.

IMPORTANT: THIS CONTROL PANEL MUST BE
MOUNTED IN A CONDITIONED SPACE.

DuroZone SMZ-SW CONTROL PANELS

Item No. 35226 SMZ-2SW 2 Zone Control Panel

Item #35226 SMZ-2SW 2 Zone Control Panel provides the contractor with a simple, low-cost zoning system for 2 zones. SMZ-2SW Panels allow for the use of a switchable sub-base (must have B & O terminals) in zone 1 to act as the system's master switch for heat, cool and fan. Moving the fan switch on the zone 1 thermostat sub-base to "ON" will activate the fan to enhance air circulation.
All SMZ Zone Systems are equipped with individual zone damper control switches. These switches will allow a zone damper to remain in either open or closed position when the system board is at rest. By setting the switches, the installer or home owner can choose the position of his system's dampers, to inhibit migration of air into spaces not desired, for seasonal purposes, or when a zone is not in use.

Item No. 35227 SMZ-3SW 3 Zone Control Panel

Item #35227 SMZ-3SW 3 Zone Control Panel provides the contractor with a simple, low-cost zoning system for 3 zones. SMZ-3SW Panels allow for the use of a switchable sub-base (must have B & O terminals) in zone 1 to act as the system's master switch for heat, cool and fan. Moving the fan switch on the zone 1 thermostat sub-base to "ON" will activate the fan to enhance air circulation.
All SMZ Zone Systems are equipped with individual zone damper control switches. These switches will allow a zone damper to remain in either open or closed position when the system board is at rest. By setting the switches, the installer or home owner can choose the position of his system's dampers, to inhibit migration of air into spaces not desired, for seasonal purposes, or when a zone is not in use.

Item No. 35228 SMZ-4SW 4 Zone Control Panel

Item #35228 SMZ-4SW 4 Zone Control Panel provides the contractor with a simple, low-cost zoning system for 4 zones. SMZ-4SW Panels allow for the use of a switchable sub-base (must have B & O terminals) in zone 1 to act as the system's master switch for heat, cool and fan. Moving the fan switch on the zone 1 thermostat sub-base to "ON" will activate the fan to enhance air circulation.
All SMZ Zone Systems are equipped with individual zone damper control switches. These switches will allow a zone damper to remain in either open or closed position when the system board is at rest. By setting the switches, the installer or home owner can choose the position of his system's dampers, to inhibit migration of air into spaces not desired, for seasonal purposes, or when a zone is not in use.

DuroZone JTZ-HP CONTROL PANEL

Item No. 35235 JTZ-HP Zone Control Panel for Heat Pumps

Item #35235 JTZ-HP 3 Zone Control Panel for Heat Pumps introduces features unique to the needs of heat pump applications. The JTZ-HP is a low cost expandable zoning system for use with heat pumps.  The JTZ-HP can control three or more zones on a single unit.  The switchable sub-base in Zone 1 acts as the selector switch for heat, cool, emergency heat and fan.  When all zones are satisfied, all zone dampers will be open to allow air circulation.  Moving the fan switch on the Zone 1 thermostat sub-base to "on" will  activate the fan to enhance air circulation.  DuroZone's JTZ-HP panel has Y1 and Y2 terminals to allow operation of heat pumps with 2 stage compressors and will operate changeover valves activated in either the heat or cool mode.

Back to Top