DUROZONE PANEL SELECTION GUIDE 
FOR HEAT PUMPS AND AUXILIARY HEAT

RED-4
  • Zone4 damper can be used as fresh air damper.  Timer on panel sets minutes of fresh air per hour.
  • Compatible with automatic change-over thermostats allowing any zone to call for heating or cooling.
  • Compatible with most 24VAC powered, battery powered thermostats.
  • Two-stage heating and two-stage cooling for gas/electric systems and Three-stage heating and two-stage cooling for heat pump system.
  • Optional supply air temperature sensor used to limit supply air temperature and prevent over-heating and freeze-up.
  • Maximum and minimum supply air temperatures can be set on the panel.
  • Optional purge cycle at the end of heating or cooling call.
  • And more...

2 TO 4 ZONES

RED-4

JTZ-HP

  • Manual Changeover
  • 2 Stage Heat, 2 Stage Cool
  • Use of Heat Pump Thermostat in all zones
  • Fossil Fuel Kit Built In
  • Simple and Proven Relay Logic

2 TO 3 ZONES

JTZ-HP